
Model:VDK-BD
Intended use:
The product is intended for the dilation or adjuvant dilation treatment for digestive tract stenosis.
Features:
1) Equipped with two radiopaque marks, easy to observe under X-ray. 2) Precise balloon size, each specification refers to only one balloon diameter. 3) Various balloon size for choose, meets different clinical demand. 4) After triplicate-wings folding, pass through 2.8mm working channel easily; safe and convenient to dilate under the observation of endoscope. 5) Made by high pressure resistance material, ensures the safety of dilation.
Specifications
Dilation balloon for ERCP:
Model |
Balloon O.D.(mm) |
Balloon Length(mm) |
Catheter Length(mm) |
Working pressure(atm) |
Characteristics |
VDK-BD-06-40-200 |
6 |
40 |
2000 |
8 |
Endoscope channel: ≥2.8mm;Guide wire diameter: 0.035" |
VDK-BD-08-40-200 |
8 |
40 |
2000 |
8 |
VDK-BD-10-40-200 |
10 |
40 |
2000 |
8 |
VDK-BD-12-40-200 |
12 |
40 |
2000 |
5 |
VDK-BD-12-60-200 |
12 |
60 |
2000 |
5 |
VDK-BD-14-40-200 |
14 |
40 |
2000 |
5 |
VDK-BD-14-60-200 |
14 |
60 |
2000 |
5 |
VDK-BD-16-40-200 |
16 |
40 |
2000 |
5 |
VDK-BD-16-60-200 |
16 |
60 |
2000 |
5 |
Dilation balloons for PTCS (percutaneous transhepatic choledochofibroscopy):
Model |
Balloon O.D.(mm) |
Balloon Length(mm) |
Catheter Length(mm) |
Working pressure(atm) |
Characteristics |
VDK-BD-06-40-90 |
6 |
40 |
900 |
8 |
Endoscope channel: ≥2.8mm;Guide wire diameter: 0.035" |
VDK-BD-08-40-90 |
8 |
40 |
900 |
8 |
Dilation balloon for Cardia:
Model |
Balloon O.D.(mm) |
Balloon Length(mm) |
Catheter Length(mm) |
Working pressure(atm) |
Characteristics |
VDK-BD-25-80-90 |
25 |
80 |
900 |
2 |
Not suitable for endoscope use; Guide wire diameter : 0.035" |
VDK-BD-30-80-90 |
30 |
80 |
900 |
2 |
VDK-BD-35-80-90 |
35 |
80 |
900 |
2 |
VDK-BD-40-80-90 |
40 |
80 |
900 |
2 |
Dilation balloon for Esophagus, Pylorus and Intestinal tract:
Model |
Balloon O.D.(mm) |
Balloon Length(mm) |
Catheter Length(mm) |
Working pressure(atm) |
Characteristics |
VDK-BD-06-40-180 |
6 |
40 |
1800 |
8 |
Endoscope channel: ≥2.8mm;Guide wire diameter:0.035" |
VDK-BD-08-40-180 |
8 |
40 |
1800 |
8 |
VDK-BD-10-40-180 |
10 |
40 |
1800 |
8 |
VDK-BD-12-60-180 |
12 |
60 |
1800 |
5 |
VDK-BD-14-60-180 |
14 |
60 |
1800 |
5 |
VDK-BD-16-80-180 |
16 |
80 |
1800 |
5 |
VDK-BD-18-60-180 |
18 |
60 |
1800 |
4 |
VDK-BD-18-80-180 |
18 |
80 |
1800 |
4 |
VDK-BD-20-60-180 |
20 |
60 |
1800 |
4 |
VDK-BD-20-80-180 |
20 |
80 |
1800 |
4 |
VDK-BD-18-80-230 |
18 |
80 |
2300 |
4 |
VDK-BD-20-60-230 |
20 |
60 |
2300 |
4 |
Endoscope channel: ≥2.8mm;Guide wire diameter: 0.035" |
VDK-BD-20-80-230 |
20 |
60 |
2300 |
4 |
Other sizes:
Model |
Balloon O.D.(mm) |
Balloon Length(mm) |
Catheter Length(mm) |
Working pressure(atm) |
Characteristics |
VDK-BD-06-40-110 |
6 |
40 |
1100 |
8 |
Endoscope channel: ≥2.8mm;Guide wire diameter:0.035" |
VDK-BD-08-40-110 |
8 |
40 |
1100 |
8 |
VDK-BD-10-40-110 |
10 |
40 |
1100 |
8 |
VDK-BD-12-40-110 |
12 |
60 |
1100 |
5 |
VDK-BD-14-60-110 |
14 |
60 |
1100 |
5 |
VDK-BD-16-80-110 |
16 |
80 |
1100 |
5 |
VDK-BD-18-80-110 |
18 |
80 |
1100 |
4 |